Electrical Characteristics

Input Characteristics (Normal Temperature Test)

  • Rated Input Voltage: 90-245VAC
  • Input Voltage Range: 85-264VAC / 70-350VDC
  • Maximum Input Voltage: ≤270VAC
  • Input Current: ≤0.2A
  • Inrush Current: ≤10A
  • Input Soft Start: ≤50ms
  • External Fuse Recommendation: 0.5A/250VAC Slow-blow Fuse
  • Input Power Efficiency: ≥69% / 70% (110/220VAC)
  • Hot Swappable: Not Supported

Output Characteristics

  • Voltage Regulation: ±0.2%
  • Load Regulation: ±0.5%
  • Startup Overshoot Amplitude: 5ms (115VAC) / 60ms (220VAC)
  • Output Short Circuit Protection: ≤5%V₀
  • Ripple & Noise: ≤70mVp-p (Tpy: 50)

Safety Features

The product design complies with UL/CE and safety certification requirements. (UL/CE certification to be completed by the customer)

Safety and Electromagnetic Compatibility

  • The input end design uses a UL-certified 0.5A fuse.
  • The PCB board is made of double-sided copper-clad laminate with a fire rating of 94-V0.
  • Safety standards compliant with UL1012, EN60950, UL60950.
  • Insulation Voltage (I/P-O/P): 2500Vac.
  • Insulation Resistance (I/P-O/P): >100M Ohms / 500Vdc 25°C 70% RH.
  • Conducted and Radiated Emissions comply with EN55011, EN55022 (CISPR22).
  • Safety standards compliant with UL1012, EN60950, UL60950.
  • ESD Immunity: IEC/EN 61000-4-2 level 4 8kV/15kV.
  • Radiated RF Immunity: IEC/EN 61000-4-3. See the application notes for details.

Temperature Rise Safety Design

  • Under normal temperature, the maximum temperature rise of the main transformer and other components does not exceed 90°C; the maximum temperature rise of the outer shell does not exceed 60°C.